DataTempDP runtime software:
============================
Version 4.0.0.15 (24.1.24)
- The receive buffer of the terminal was to small for the GConfig command.
- Saving the zone history was impaired in version 4.0.0.6. This is corrected now.
Plus additional "...now with version 4.0.0.15 the Internal Temperature is now working correctly when mapped to a Wago channel output."
Version 4.0.0.14 (21.9.23)
- The process speed synchronization did not work with the voltage input.
- OPC-UA: The internal temperature was shown in °C only. Now it can be shown in °F too.
- OPC-UA: The item “TemperatureUnit” (read only) was added.
- The SnapshotView is disabled now for continuous applications (EC, ES).
Version 4.0.0.13 (24.8.23)
- TStream files can be saved now automatically (in time intervals), with automatically created names.
Version 4.0.0.12 (28.7.23)
- "Emissivity via voltage" and "Ambient compensation via voltage" mutual excluded.
- The Adaptive Alarm was made available also for the bottom alarm.
Version 4.0.0.11 (16.6.2023)
- The remembering of the windows position includes now also the min/max state.
Version 4.0.0.9 (30.11.2022)
- The maximal length of a snapshot was enlarged to 5000lines.
- If triggering was configured to rising/falling edge a communication error stopped a started snapshot. Now the communication error
gets ignored for start/stop of a snapshot.
Version 4.0.0.7 (2.8.2022)
- OPC-DA: The internal temperature was updated at the end of a snapshot only. It gets updated now also without a snapshot.
This is especially of interest at the launch of the program, before the first snapshot.
Version 4.0.0.6 (22.4.2022)
- Update of the OPC-UA library to open65241 version 1.3.
- The envelop in the ProfileView is remembered now after closing the program.
- The alarm limits of a sector are shown now in the HorizontalProfile, using a red/blue-dashed line.
Version 4.0.0.5 (7.4.2022)
- The alarm limits of a sector are shown now in the HorizontalProfile, using a red-dashed line.
Version 4.0.0.4 (31.3.2022)
- Support of OPC-UA.
- Correction of the emissivity-calculation in the SnapshotView for 1M, 2M and 3M.
Version 4.0.0.3 (11.10.2021)
- New install system. It does not care for installations before version 4.0.0.3, but it works with the current Windows.
- In the snapshotView it is possible to set the safe conditions. There it is possible to set conditions in such a way
that not every snapshot will be safed. This was true also for the consecutive zone results.
Now the format "consecutive zone results" will save the result for every snapshot, not only for a selection.
Version 4.0.0.2 (6.7.2021)
- Error in the usage of the time stamp corrected in the HistoryView.
- The Forwarded Results did not represent the true live value of pixel count.
- In some rare cases the internal sectors (device sectors) were not positioned correctly.
Version 4.0.0.0 (17.5.2021)
- The "150" was taken away from all names. This implies unfortunately, that you have to uninstall your previous
version before installing this version.
- The internal zones with Wago option are available now also for Raytek scanners.
- In case of using only a section of the scan-line: The forward protocol did send the pixel count of the complete line.
(But only the section-count of pixels contained correct data.)
- Generic zones were introduced.